FireFlo System Sizing

FireFlo System Sizing

Calculating the size of your heat collector system

To work out the number of FireFlo collectors you need, gather the following information together:

    • The maximum power output for your heat pump, in kW
    • Determine the minimum temperature of your watercourse and brine flow and return temperatures (if in doubt and in the UK, the 5 °C river temp and -4 to 0°C brine temp would be a reasonable starting point for a typical UK site).
    • Determine the river flow velocity (the speed that the water flows at) where the FireFlo collectors will be located, in metres/second. Assuming you don’t have a flow velocity meter to hand, you can get a good indication of flow velocity by half-filling a plastic soft drinks bottle with water, put it in the water and time how long it takes to float past two markers of a known distance apart. The flow velocity can then be calculated using:

Velocity (m/s) = distance between the two markers (m) / time to float between the two markers (s)

    • Decide how will the collectors be mounted:

a) Fully surrounded by flow (wall-mounted, bed-mounted vertical panel or bed-mounted horizontal panel) – use the FireFlo Single Panel Thermal Output graph below for sizing.

FireFlo thermal output when wall mounted (5°C river temp. -4 to 0°C brine temp. is used for a typical UK sizing).

FireFlo thermal output when wall mounted (5°C river temp. -4 to 0°C brine temp. is used for a typical UK sizing).

b) Bed-mounted, embedded – use the FireFlo Embedded Panel Thermal Output graph below for sizing.

FireFlo Embedded Panel Thermal Output graph

FireFlo Embedded Panel Thermal Output graph

Then, using the appropriate graph below depending on how your panels will be mounted, find your river velocity on the x-axis (horizontal axis), then draw a vertical line upwards until it intersects with the line that corresponds to the minimum temperature of your watercourse and brine flow and return temperature, then read the ‘Thermal Output (kW)’ from the y-axis (vertical axis) that corresponds with this point.

Then number of FireFlo collector panels is calculated by:

No. of FireFlo panels = Maximum power output for your heat pump, in kW / Thermal Output (kW)

Then whatever number this calculates, round-up to the next whole number.

For example, assuming you required:

Max power output from your heat pump = 13 Kw
At a typical UK site (5 °C min. river temp, -4 to 0°C brine temp)
Flow velocity past the collectors is 0.2 m/s
To be mounted fully-surrounded by the flow.

FireFlo Single Panel Thermal Output graph

FireFlo Single Panel Thermal Output graph

No. of panels required = 15 kW / 5.5 kW = 2.72 panels, rounded up to 3 panels required.

Budget pricing

The exact price depends on the layout and mounting system used, but if you assume £1,950 per FireFlo collector panel, and £250 per panel for the mounting system (Note this excludes the fixings to whatever it is being fixed to, and the installation cost).

Lead time

The FireFlo panels are made-to-order with a typical lead time of 5 weeks from payment of deposit. Note the panel will not be dispatched until payment in full has been received.

Are you considering a FireFlo heat collector ?

FireFlo heat collectors are now installed and operating in rivers in the UK, as an essential component to Water Source Heat Pump installations. FireFlo heat collectors are designed and manufactured in Britain. Our FireFlo collectors are available in the United Kingdom and the European Union or other countries by agreement. Your first step is to check our Design Guide , Sizing and Pricing Guide and our Installation Guide. Interested? Please Get in touch

If you would like more information or a quote please us the Enquiry page or call us on +44 (0)1453 88 77 44.

Pin It on Pinterest

Share This