<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Case Studies Archives - Fireflo</title>
	<atom:link href="https://fireflo.co.uk/category/casestudies/feed/" rel="self" type="application/rss+xml" />
	<link>https://fireflo.co.uk/category/casestudies/</link>
	<description>The water source heat pump heat collector system</description>
	<lastBuildDate>Tue, 28 Jun 2022 11:10:00 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://fireflo.co.uk/wp-content/uploads/2022/06/favicon-2.ico</url>
	<title>Case Studies Archives - Fireflo</title>
	<link>https://fireflo.co.uk/category/casestudies/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Case Study &#8211; Brimscombe Port Mill</title>
		<link>https://fireflo.co.uk/fireflo/case-study-brimscombe-port-mill/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Tue, 07 Jun 2022 10:35:16 +0000</pubDate>
				<category><![CDATA[Brimscombe Port Mill]]></category>
		<category><![CDATA[Case Studies]]></category>
		<category><![CDATA[Fireflo]]></category>
		<category><![CDATA[High Profile Posts]]></category>
		<category><![CDATA[Projects]]></category>
		<guid isPermaLink="false">https://fireflo.co.uk/?p=3114</guid>

					<description><![CDATA[<p>As part of the local council’s commitment to net zero carbon emissions, the existing gas boiler system was removed at Brimscombe Port Mill and a heat pump system utilising FireFlo collectors was installed.</p>
<p>The post <a href="https://fireflo.co.uk/fireflo/case-study-brimscombe-port-mill/">Case Study &#8211; Brimscombe Port Mill</a> appeared first on <a href="https://fireflo.co.uk">Fireflo</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><div id="attachment_3116" style="width: 1010px" class="wp-caption alignleft"><a href="https://fireflo.co.uk/wp-content/uploads/2022/06/1-1.jpg"><img fetchpriority="high" decoding="async" aria-describedby="caption-attachment-3116" class="size-full wp-image-3116" src="https://fireflo.co.uk/wp-content/uploads/2022/06/1-1.jpg" alt="Main flow and return manifolds for the FireFlo collector system with FireFlo panels submerged below" width="1000" height="750" srcset="https://fireflo.co.uk/wp-content/uploads/2022/06/1-1.jpg 1000w, https://fireflo.co.uk/wp-content/uploads/2022/06/1-1-980x735.jpg 980w, https://fireflo.co.uk/wp-content/uploads/2022/06/1-1-480x360.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1000px, 100vw" /></a><p id="caption-attachment-3116" class="wp-caption-text">Main flow and return manifolds for the FireFlo collector system with FireFlo panels submerged below</p></div><br />
Download a copy of the Brimscombe Port Mill FireFlo case study <a href="https://fireflo.co.uk/wp-content/uploads/2022/06/FireFlo-Brimscombe-Port-case-study.pdf">here</a>.</p>
<div>
<table width="75%">
<colgroup>
<col width="40%" />
<col width="60%" /></colgroup>
<caption style="caption-side: bottom;">Brimscombe port installation details</caption>
<tbody>
<tr>
<td>Site location</td>
<td>Brimscombe Port, Stroud</td>
</tr>
<tr>
<td>Year of install</td>
<td>2021</td>
</tr>
<tr>
<td>Heat pump maximum thermal output</td>
<td>180 kW</td>
</tr>
<tr>
<td>Number of FireFlo panels</td>
<td>35</td>
</tr>
<tr>
<td>Installation arrangement</td>
<td>15 x wall mounted panels<br />
(5 x 3 panel assemblies with flow and return to each panel)<br />
20 x non-standard vertical bed mounted<br />
(10 x 2 panel assemblies connected in two banks of 5)</td>
</tr>
</tbody>
</table>
</div>
<p>As part of the local council’s commitment to net zero carbon emissions, the existing gas boiler system was removed at Brimscombe Port Mill and a heat pump system utilising FireFlo collectors was installed.</p>
<p>The FireFlo assemblies are installed directly in the flow of the river. A combination of panels mounted directly to the masonry wall and panels mounted to the river bed has been used.</p>
<p>The various collector loops have been connected to flow and return manifolds with commissioning valves used to balance the flow through each loop.</p>
<div id="attachment_3120" style="width: 1010px" class="wp-caption alignleft"><a href="https://fireflo.co.uk/wp-content/uploads/2022/06/2-1.jpg"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-3120" class="size-full wp-image-3120" src="https://fireflo.co.uk/wp-content/uploads/2022/06/2-1.jpg" alt="Vertical bed mounted FireFlo panels (centre) alongside wall mounted panels (left)" width="1000" height="750" srcset="https://fireflo.co.uk/wp-content/uploads/2022/06/2-1.jpg 1000w, https://fireflo.co.uk/wp-content/uploads/2022/06/2-1-980x735.jpg 980w, https://fireflo.co.uk/wp-content/uploads/2022/06/2-1-480x360.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1000px, 100vw" /></a><p id="caption-attachment-3120" class="wp-caption-text">Vertical bed mounted FireFlo panels (centre) alongside wall mounted panels (left)</p></div>
<p>The bed mounted assemblies were connected in reverse return configuration using stainless steel manifolds manufactured by Renewables First, (see image below).</p>
<div id="attachment_3121" style="width: 1010px" class="wp-caption alignleft"><a href="https://fireflo.co.uk/wp-content/uploads/2022/06/3-1.jpg"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-3121" class="size-full wp-image-3121" src="https://fireflo.co.uk/wp-content/uploads/2022/06/3-1.jpg" alt="Vertical bed mounted panels connected in reverse return configuration" width="1000" height="750" srcset="https://fireflo.co.uk/wp-content/uploads/2022/06/3-1.jpg 1000w, https://fireflo.co.uk/wp-content/uploads/2022/06/3-1-980x735.jpg 980w, https://fireflo.co.uk/wp-content/uploads/2022/06/3-1-480x360.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1000px, 100vw" /></a><p id="caption-attachment-3121" class="wp-caption-text">Vertical bed mounted panels connected in reverse return configuration</p></div>
<p>As the installation area was submerged during installation, the flow and the return pipework was partially assembled prior to installation to prevent contaminated water entering the system (see image below). This image also shows how the assembly was slung from both ends during the lifting process, in line with the <a href="https://fireflo.co.uk/installation/">FireFlo Installation and Maintenance Guide</a>.</p>
<p>&nbsp;</p>
<div id="attachment_3124" style="width: 1010px" class="wp-caption alignleft"><a href="https://fireflo.co.uk/wp-content/uploads/2022/06/4-1.jpg"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-3124" class="size-full wp-image-3124" src="https://fireflo.co.uk/wp-content/uploads/2022/06/4-1.jpg" alt="3 panel FireFlo assembly being lowered into the watercourse" width="1000" height="750" srcset="https://fireflo.co.uk/wp-content/uploads/2022/06/4-1.jpg 1000w, https://fireflo.co.uk/wp-content/uploads/2022/06/4-1-980x735.jpg 980w, https://fireflo.co.uk/wp-content/uploads/2022/06/4-1-480x360.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1000px, 100vw" /></a><p id="caption-attachment-3124" class="wp-caption-text">3 panel FireFlo assembly being lowered into the watercourse</p></div>
<div id="attachment_3225" style="width: 1010px" class="wp-caption alignnone"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-3225" class="size-full wp-image-3225" src="https://fireflo.co.uk/wp-content/uploads/2022/06/DSC_1336.jpg" alt="20 off bed-mounted vertical FireFlo heat collectors after one year of operation" width="1000" height="750" srcset="https://fireflo.co.uk/wp-content/uploads/2022/06/DSC_1336.jpg 1000w, https://fireflo.co.uk/wp-content/uploads/2022/06/DSC_1336-980x735.jpg 980w, https://fireflo.co.uk/wp-content/uploads/2022/06/DSC_1336-480x360.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1000px, 100vw" /><p id="caption-attachment-3225" class="wp-caption-text">20 off bed-mounted vertical FireFlo heat collectors after one year of operation</p></div>
<div id="attachment_3226" style="width: 1010px" class="wp-caption alignnone"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-3226" class="size-full wp-image-3226" src="https://fireflo.co.uk/wp-content/uploads/2022/06/DSC_1329.jpg" alt="2 rows of 3-panel FireFlo wall-mounted assemblies after one year of operation" width="1000" height="750" srcset="https://fireflo.co.uk/wp-content/uploads/2022/06/DSC_1329.jpg 1000w, https://fireflo.co.uk/wp-content/uploads/2022/06/DSC_1329-980x735.jpg 980w, https://fireflo.co.uk/wp-content/uploads/2022/06/DSC_1329-480x360.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1000px, 100vw" /><p id="caption-attachment-3226" class="wp-caption-text">2 rows of 3-panel FireFlo wall-mounted assemblies after one year of operation</p></div>
<p>The post <a href="https://fireflo.co.uk/fireflo/case-study-brimscombe-port-mill/">Case Study &#8211; Brimscombe Port Mill</a> appeared first on <a href="https://fireflo.co.uk">Fireflo</a>.</p>